Emergency equipment
§393.95 Emergency equipment on all power units.
Each truck, truck tractor, and bus (except those towed in
driveaway-towaway operations) must be equipped as follows:
(a) Fire Extinguishers
(a)(1)
Minimum ratings:
(a)(1)(i) A power unit that is used to
transport hazardous materials in a quantity that requires placarding (See
§177.823 of this title) must be equipped with a fire extinguisher having an
Underwriters’ Laboratories rating of 10 B:C or more.
(a)(1)(ii) A power unit that is not used
to transport hazardous materials must be equipped with either:
(a)(1)(ii)(A) A fire extinguisher having an
Underwriters’ Laboratories rating of 5 B:C or more; or
(a)(1)(ii)(B) Two fire extinguishers, each
of which has an Underwriters’ Laboratories rating of 4 B:C or more.
(a)(2)
Labeling and marking.
Each fire extinguisher required by this section must be labeled or marked by
the manufacturer with its Underwriters’ Laboratories rating.
(a)(3)
Visual Indicators.
The fire extinguisher must be designed, constructed, and maintained to permit
visual determination of whether it is fully charged.
(a)(4)
Condition, location, and mounting.
The fire extinguisher(s) must be filled and located so that it is readily
accessible for use. The extinguisher(s) must be securely mounted to prevent
sliding, rolling, or vertical movement relative to the motor vehicle.
(a)(5)
Extinguishing agents.
The fire extinguisher must use an extinguishing agent that does not need
protection from freezing. Extinguishing agents must comply with the toxicity
provisions of the Environmental Protection Agency’s Significant New
Alternatives Policy (SNAP) regulations under 40 CFR Part 82, Subpart
G.
(a)(6)
Exception.
This paragraph (a) does not apply to the driven unit in a driveaway-towaway
operation.
(b)
Spare fuses.
Power units for which fuses are needed to operate any required parts and
accessories must have at least one spare fuse for each type/size of fuse needed
for those parts and accessories.
(c)–(e) [Reserved]
(f) Warning devices for stopped vehicles. Except as provided in
paragraph (g) of this section, one of the following options must be
used:
(f)(1) Three bidirectional emergency
reflective triangles that conform to the requirements of Federal Motor Vehicle
Safety Standard No. 125, §571.125 of this title; or
(f)(2) At least 6 fusees or 3
liquid-burning flares. The vehicle must have as many additional fusees or
liquid-burning flares as are necessary to satisfy the requirements of
§392.22.
(f)(3) Other warning devices may be used
in addition to, but not in lieu of, the required warning devices, provided
those warning devices do not decrease the effectiveness of the required warning
devices.
(g) Restrictions on the use of flame-producing devices.
Liquid-burning flares, fusees, oil lanterns, or any signal produced by a flame
shall not be carried on any commercial motor vehicle transporting Division 1.1,
1.2, 1.3 (explosives) hazardous materials; any cargo tank motor vehicle used
for the transportation of Division 2.1 (flammable gas) or Class 3 (flammable
liquid) hazardous materials whether loaded or empty; or any commercial motor
vehicle using compressed gas as a motor fuel.
(h)–(i) [Reserved]
(j) Requirements for fusees and liquid-burning flares. Each fusee
shall be capable of burning for 30 minutes, and each liquid-burning flare shall
contain enough fuel to burn continuously for at least 60 minutes. Fusees and
liquid-burning flares shall conform to the requirements of Underwriters
Laboratories, Inc., UL No. 912, Highway Emergency Signals, Fourth Edition, July
30, 1979, (with an amendment dated November 9, 1981). (See §393.7(c) for
information on the incorporation by reference and availability of this
document.) Each fusee and liquid-burning flare shall be marked with the UL
symbol in accordance with the requirements of UL 912.
(k) Requirements for red flags. Red flags shall be not less than
12 inches square, with standards adequate to maintain the flags in an upright
position.
[33 FR 19735, Dec. 25, 1968, as amended at 35 FR 13019, Aug. 15,
1970; 35 FR 14619, Sept. 18, 1970; 37 FR 17176, Aug. 25, 1972; 40 FR 10685,
Mar. 7, 1975; 41 FR 53031, Dec. 3, 1976; 47 FR 47837, Oct. 28, 1982, 59 FR
34712, July 6, 1994; 67 FR 61225, Sept. 27, 2002; 70 FR 48055, Aug. 15,
2005; 72 FR 44036, Oct. 1, 2007]