You are here

  • § 325.1
    Scope of the rules in this part.
  • § 325.3
    Effective date.
  • § 325.5
    Definitions.
  • § 325.7
    Allowable noise levels.
  • § 325.9
    Measurement tolerances.
  • § 325.11
    Issuance, amendment, and revocation of the rules in this part.
  • § 325.13
    Inspection and examination of motor vehicles.
  • § 325.21
    Scope of the rules in this subpart.
  • § 325.23
    Type of measurement systems which may be used.
  • § 325.25
    Calibration of measurement systems.
  • § 325.27
    Use of a windscreen.
  • § 325.31
    Scope of the rules in this subpart.
  • § 325.33
    Site characteristics; highway operations.
  • § 325.35
    Ambient conditions; highway operations.
  • § 325.37
    Location and operation of sound level measurement system; highway operations.
  • § 325.39
    Measurement procedure; highway operations.
  • § 325.51
    Scope of the rules in this subpart.
  • § 325.53
    Site characteristics; stationary test.
  • § 325.55
    Ambient conditions; stationary test.
  • § 325.57
    Location and operation of sound level measurement systems; stationary test.
  • § 325.59
    Measurement procedure; stationary test.
  • § 325.71
    Scope of the rules in this subpart.
  • § 325.73
    Microphone distance correction factors.
  • § 325.75
    Ground surface correction factors.
  • § 325.77
    Computation of open site requirements—nonstandard sites.
  • § 325.79
    Application of correction factors.
  • § 325.91
    Exhaust systems.
  • § 325.93
    Tires.

Part 325
COMPLIANCE WITH INTERSTATE MOTOR CARRIER NOISE EMISSION STANDARDS

§ 325.77: Computation of open site requirements—nonstandard sites.

(a) If the distance between the microphone location point and the microphone target point is other than 50 feet (15.2 m), the test site must be an open site within a radius from both points which is equal to the distance between the microphone location point and the microphone target point.
(b) Plan view diagrams of nonstandard test sites are shown in Figures 3 and 4. Figure 3 illustrates a test site which is larger than a standard test site and is based upon a 60-foot (18.3 m) distance between the microphone location point and the microphone target point. (See § 325.79(b)(1) for an example of the application of the correction factor to a sound level reading obtained at such a site.) Figure 4 illustrates a test site which is smaller than a standard test site and is based upon a 35-foot (10.7 m) distance between the microphone location point and the microphone target point. (See § 325.79(b)(2) for an example of the application of the correction factor to a sound level reading obtained at such a site.)